PFAS Remediation Systems for Contaminated Water and Landfill Leachate

Who else needs a PFAS remediation systems that remove PFAS, including PFOA and PFOS, from contaminated water and landfill leachate?

Each system built uses granular activated carbon (GAC), ion exchange resin, or both in series, and we supply it as a mobile rental or a permanent installation.

Click To End Your PFAS Problems

How GAC and Ion Exchange Remove PFAS

PFAS contamination does not break down in conventional water treatment, so remediation works by capturing them on media and then removing the loaded media for disposal or reactivation.

The two media capture PFAS in different ways, and the right choice depends on which compounds are present and at what concentration.

Granular activated carbon used for PFAS removal

Granular activated carbon

GAC adsorbs PFAS onto the surface of carbon granules as water passes through a vessel.

It works well on long-chain compounds such as PFOA and PFOS, and it also removes other organic contaminants in the same water.

Short-chain PFAS break through carbon sooner, which shortens bed life.

Ion exchange resin beads used for PFAS removal

Ion exchange resin

Ion exchange resin holds PFAS by exchanging ions as water passes through the bed.

It targets both short-chain and long-chain PFAS, including PFOA and PFOS, and it is often selected where short-chain compounds drive the treatment target.

Carbon and resin in series

Many projects use carbon and resin vessels in series, which spreads removal across both media and covers a wider mix of compounds. A vessel train will be sized from your influent data, and we can quote a carbon system and a resin system side by side so you can compare them.

Request a Quote

What's needed to Size and Quote a PFAS System

A usable quote starts with a few site facts. Send them with your request if you have them.

If you do not have them yet, we can begin with a site visit, where we sample the water with test equipment and send it to a certified laboratory for analysis.

  1. Flow rate in GPM, with peak and average flow if they differ.
  2. Total PFAS concentration in ng/L and the compounds reported, with the lab results attached.
  3. The limit you must meet, such as a drinking water standard or a discharge permit limit.
  4. Influent water chemistry, especially iron and suspended solids.
  5. Project duration, and whether you plan to rent or buy.
Request a Quote

Mobile Rental or Permanent Installation

Short projects and emergencies do not need capital equipment.

10 to 5,000 GPM

Voyager

The Voyager mobile water purification system runs from 10 to 5,000 GPM and serves emergency deployments and permanent setups alike, and a rental unit can be operational within days.

Smaller flows

Mini Skid

The Mini Skid is a portable, light system for smaller flows.

Sites with a long-term cleanup, such as a landfill leachate stream, are better served by a permanent system built to the site's flow and chemistry, and we operate and maintain the systems we build. You can compare every unit on our mobile water filtration page.

Pretreatment and Water Chemistry

Iron and suspended solids foul media and shorten the time between change-outs, so your influent chemistry will be reviewed before selecting vessels and prefiltration. 

Importantly, landfill leachate and groundwater with high iron often need prefiltration ahead of the PFAS vessels, and the right arrangement depends on your sample data.

Where these PFAS Systems Have Been Used

PFAS projects are documented in case studies you can read before you contact us.

PFAS Limits Vary by State and Water Use

The limit your system must meet depends on your state and on what happens to the water afterward.

Federal, state, and local PFAS rules are changing, so we design to the limit that applies to your site and the date you must meet it. This PFAS regulations guide covers the rules that apply to industrial manufacturers.

Benefits of PFAS Remediation

Our PFAS filtration team designs each system to the limit that applies to your site, then handles the sampling, analysis, data review and maintenance that keep the system on target.

Emergency response service
Safe and secure sample collection
Sample analysis through EPA-certified laboratories
Data review and system maintenance
Removal of PFOA, PFOS, and other PFAS contaminants

Site Visit and Testing

Call 248-427-9090 to schedule a site visit with test equipment and EPA-certified laboratory analysis. The results give you the information you need to make an informed decision.

Get a Free PFAS Removal System Assessment

Quality

Underperforming equipment and suppliers who disappear when problems come up cost you time. We have spent four decades improving both our products and our service.

Our ISO 9001:2015 certification and our repeat customers show that the work holds up.

40+Years in business
ISO 9001:2015Certified

PFAS Remediation FAQs

These answers cover the questions that come up in the inquiries we receive.

PFAS remediation is the process of removing PFAS from contaminated water or landfill leachate so that it meets the limit that applies to its use or discharge. 

For water, remediation usually means passing it through granular activated carbon, ion exchange resin, or both in series.

Neither is better in every case. 

GAC is well established for long-chain PFAS such as PFOA and PFOS.

Ion exchange resin removes both short-chain and long-chain PFAS, so it is often the choice when short-chain compounds appear in your lab results. Many systems use both. 

You will get a formal recommendation of media type after reviewing your sample data.

Yes. Mobile PFAS treatment systems are ready for emergencies and short projects, including the Voyager system from 10 to 5,000 GPM, so you do not have to buy equipment for a temporary need. 

Permanent systems are available for long-term PFAS removal.

Cost depends on flow rate, PFAS concentration, the limit you must meet, water chemistry, and whether you rent or buy. 

Prices cannot be published because every site is different. Send your flow rate and lab results with a quote request and we will price a system to your site, contamination levels and requirements.

Rental systems can be operational within days. Permanent systems take longer because they are built to the site's flow and chemistry, and we confirm the schedule when we quote.

Yes. We operate and maintain the PFAS systems we build, including data review and system maintenance.

Yes. Our landfill leachate PFAS project is documented in a case study. Leachate can carry higher PFAS concentrations than groundwater, so we size prefiltration and media to your sample data.

Request a PFAS Quote

Send your flow rate and PFAS lab results with the limit you need to meet, and our team will review your project. You can also call 248-427-9090 to talk to a specialist.

Request a Quote
Trusted partner

Your Trusted Partner for Success

Our team of expert engineers, project managers and client services are always on your side.

Our goal is to help you get the right filtration and separation system for your manufacturing facility that confidently, reliably and measurably performs as promised.

Just imagine the impact the right filtration system could have on your manufacturing efficiency and your bottom line.

contact our experts today